Please use this identifier to cite or link to this item: https://dspace.ncfu.ru/handle/123456789/32167
Title: Determination of Endocrine Disruptors in Bottom Sediments by Gas Chromatography–Mass Spectrometry with Analyte Preconcentration by Liquid–Liquid and Magnetic Dispersive Solid-Phase Extraction
Authors: Sypko, K. S.
Сыпко, К. С.
Keywords: Preconcentration;Alkylphenols;Bisphenol A;Bottom sediments;Determination;Dialkyl phthalates;Magnetic dispersive solid-phase extraction;Endocrine disruptors
Issue Date: 2025
Publisher: Pleiades Publishing
Citation: Gubin, A.S., Sypko, K.S., Kushnir, A.A., Sukhanov, P.T. Determination of Endocrine Disruptors in Bottom Sediments by Gas Chromatography–Mass Spectrometry with Analyte Preconcentration by Liquid–Liquid and Magnetic Dispersive Solid-Phase Extraction // Journal of Analytical Chemistry. - 2025. - 80 (9). - pp. 1561 - 1574. - DOI: 10.1134/S1061934825700777
Series/Report no.: Journal of Analytical Chemistry
Abstract: A method is proposed for the extraction and preconcentration of six of the most common endocrine disruptors (dimethyl, diethyl, dibutyl phthalates; bisphenol A; and octyl- and nonylphenols) from river bottom sediments. The analytes are extracted by two-stage preconcentration. At the first stage, the analytes are extracted from an aqueous solution with an ionic liquid, 1-hexyl-3-methylimidazolium hexafluorophosphate in the presence of a surfactant (sodium dodecyl sulfate). The volumes of the extractant and surfactant solution (12 vol %) are 200 μL and 0.5 mL, respectively. Extraction duration is 2 min. At the second stage, magnetic dispersive solid-phase extraction with magnetic coals of plant origin modified with reversed phases of n-octyltrimethoxysilane and n-octadecyltrimethoxysilane is used. The recovery of analytes by liquid–liquid extraction is 91–99% and by magnetic solid-phase dispersive extraction, 89–99%. It is found that, during solid-phase dispersive extraction, the best conditions for the extraction of disruptors are achieved at pH 5.2–7.0, sorption duration of 5 min using a centrifuge (4000 rpm), and sorbent portion of 25 mg. The use of two-stage preconcentration in combination with gas chromatography–mass spectrometry ensures the determination of endocrine disruptors in bottom sediments at a level of 0.4–0.7 μg/kg.
URI: https://dspace.ncfu.ru/handle/123456789/32167
Appears in Collections:Статьи, проиндексированные в SCOPUS, WOS

Files in This Item:
File Description SizeFormat 
scopusresults 3698.pdf
  Restricted Access
128.86 kBAdobe PDFView/Open
WoS 2208.pdf
  Restricted Access
117.29 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.