Please use this identifier to cite or link to this item: https://dspace.ncfu.ru/handle/20.500.12258/15854
Title: Membrane purification of secondary milk raw materials: Intensification of processes
Authors: Khramtsov, A. G.
Храмцов, А. Г.
Babenyshev, S. P.
Бабенышев, С. П.
Mamay, D. S.
Мамай, Д. С.
Nurullo, M.
Нурулло, М.
Mamay, A. V.
Мамай, А. В.
Keywords: Biotechnology;Dairies;Preliminary treatment;Working pressures;Baromembrane process;Circulation rates;Deep processing;Human communities;Membrane purification;Operating parameters;Purification
Issue Date: 2021
Publisher: IOP Publishing Ltd
Citation: Khramtsov, A.G., Babenyshev, S.P., Zhidkov, V.E., Mamay, D.S., Nurullo, M., Mamay, A.V. Membrane purification of secondary milk raw materials: Intensification of processes // IOP Conference Series: Earth and Environmental Science. - 2021. - Volume 677. - Issue 3. - Номер статьи 032060
Series/Report no.: IOP Conference Series: Earth and Environmental Science
Abstract: Further development of the human community depends on two main tasks to be performed, i.e. providing the population with high-grade food and preserving the environment due to the rational use of natural raw materials. In this regard, processing of secondary milk raw materials is considered a controlled impact on a complex biotechnological system. The impact was divided into preliminary treatment and final processing and is based on two principles; firstly, secondary dairy raw materials must be standardized before the initial stage of its deep processing, involving fractionation; and secondly, the first step of the baromembrane purification of secondary milk raw materials should ensure the purification of the permeate from proteins and milk fat. The purpose of the study was to theoretically substantiate and experimentally determine the optimal operating parameters of the baromembrane processes in the technology for obtaining highly purified whey permeate. The authors have experimentally established that the deep baromembrane purification of milk whey ensures the optimal values of the working pressure and circulation rate of the separated system that are P= 0.45-0.5 MPa and V=0.15-0.2 m/sec in the channel of the ultrafiltration apparatus and P=1.5-2.5 MPa and V=0.16-0.26 m/sec in the channel of the nanofiltration apparatus, respectively
URI: http://hdl.handle.net/20.500.12258/15854
Appears in Collections:Статьи, проиндексированные в SCOPUS, WOS

Files in This Item:
File SizeFormat 
scopusresults 1646 .pdf
  Restricted Access
459.55 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.