Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс:
https://dspace.ncfu.ru/handle/20.500.12258/3230Полная запись метаданных
| Поле DC | Значение | Язык |
|---|---|---|
| dc.contributor.author | Zelensky, E. G. | - |
| dc.contributor.author | Зеленский, Е. Г. | - |
| dc.contributor.author | Kononov, Y. G. | - |
| dc.contributor.author | Кононов, Ю. Г. | - |
| dc.contributor.author | Levchenko, I. I. | - |
| dc.contributor.author | Левченко, И. И. | - |
| dc.date.accessioned | 2018-10-11T13:21:25Z | - |
| dc.date.available | 2018-10-11T13:21:25Z | - |
| dc.date.issued | 2016 | - |
| dc.identifier.citation | Zelenskii, E.G., Kononov, Y.G., Levchenko, I.I. Identification of the parameters of distribution networks by synchronized current and voltage measurements // Russian Electrical Engineering. - 2016. - Volume 87. - Issue 7. - Pages 363-368 | ru |
| dc.identifier.uri | https://www.scopus.com/record/display.uri?eid=2-s2.0-84987740601&origin=resultslist&sort=plf-f&src=s&nlo=&nlr=&nls=&sid=533b00ecafed28ec57b975efc6ad38be&sot=aff&sdt=cl&cluster=scopubyr%2c%222016%22%2ct&sl=174&s=AF-ID%28%22North+Caucasus+Federal+University%22+60070541%29+OR+AF-ID%28%22Stavropol+State+University%22+60070961%29+OR+AF-ID%28%22stavropolskij+Gosudarstvennyj+Tehniceskij+Universitet%22+60026323%29&relpos=44&citeCnt=0&searchTerm= | - |
| dc.identifier.uri | http://hdl.handle.net/20.500.12258/3230 | - |
| dc.description.abstract | On the basis of synchronized measurements of current and voltage phasors, a technique for identification of parameters of 0.4- and 6- to 10-kV lines is suggested. The technique is based on the methods of statistical processing of sets of network modes and composed of several steps. The first step is acquisition of statistical data on network modes. It involves periodic measurements of synchronized current and voltage phasors at injection nodes. The second step is direct statistical processing of the obtained information using the method of least squares. The technique was tested using a three–phase physical model of a network. The mean error of identification of resistance and reactance was approximately 0.5 and 1%, respectively | ru |
| dc.language.iso | en | ru |
| dc.publisher | Allerton Press Incorporation | ru |
| dc.relation.ispartofseries | Russian Electrical Engineering | - |
| dc.subject | Distribution networks | ru |
| dc.subject | Identification of network parameters | ru |
| dc.subject | Synchronized measurement | ru |
| dc.subject | Vector recorders | ru |
| dc.subject | Parameter estimation | ru |
| dc.title | Identification of the parameters of distribution networks by synchronized current and voltage measurements | ru |
| dc.type | Статья | ru |
| vkr.amount | Pages 363-368 | ru |
| vkr.inst | Инженерный институт | - |
| Располагается в коллекциях: | Статьи, проиндексированные в SCOPUS, WOS | |
Файлы этого ресурса:
| Файл | Описание | Размер | Формат | |
|---|---|---|---|---|
| scopusresults 437 .pdf Доступ ограничен | 302.66 kB | Adobe PDF | Просмотреть/Открыть |
Все ресурсы в архиве электронных ресурсов защищены авторским правом, все права сохранены.