Please use this identifier to cite or link to this item: https://dspace.ncfu.ru/handle/123456789/31835
Title: Finite difference method for estimating the density of loess compacted by explosion
Authors: Tarasenko, E. O.
Тарасенко, Е. О.
Keywords: Compaction by deep explosions;Subsidence;Soil density;Loess;Finite difference method;Crank–nicholson scheme
Issue Date: 2025
Publisher: Tomsk Polytechnic University, Publishing House
Citation: Tarasenko, E. O. Finite difference method for estimating the density of loess compacted by explosion // Bulletin of the Tomsk Polytechnic University Geo Assets Engineering. - 2025. - 336 (6). - pp. 76 - 83. - DOI: 10.18799/24131830/2025/6/4787
Series/Report no.: Bulletin of the Tomsk Polytechnic University, Geo Assets Engineering
Abstract: The need for preliminary numerical modeling of the density assessment of loess compacted by deep blasts in order to reduce economic costs during production work. Soil subsidence was eliminated at the stages of design and construction of buildings and structures to ensure their safe, long-term operation. Loess subsidence soils are widespread throughout the world, often in Europe and Asia. Loess is characterized by low density of the soil skeleton, high dust content, and macroporosity. Aim. To numerically estimate the density of soil after compaction by deep blasting using the finite difference method. Methods. Finite difference method; computational experiment; numerical modeling. Results and conclusions. To solve initial boundary problems within the framework of mathematical modeling of loess compaction by deep explosions, the finite difference method was used. The model is based on a parabolic differential equation. A six-point symmetrical Crank–Nicholson circuit was used. The constructed linear systems of equations take into account the initial and boundary conditions, the input effects of the soil diffusion coefficient, the power of the explosive charge, and the vector of horizontal gas distribution. The result of solving the systems are the values of soil density at the nodes of the grid function. The estimate of soil density found by the finite difference method has second order accuracy in spatial coordinates and time. The constructed six-point circuits are absolutely stable. A computational experiment was implemented using the proposed method for assessing soil density, which showed adequacy to the experimental data of a natural construction site.
URI: https://dspace.ncfu.ru/handle/123456789/31835
Appears in Collections:Статьи, проиндексированные в SCOPUS, WOS

Files in This Item:
File Description SizeFormat 
scopusresults 3641.pdf
  Restricted Access
125.35 kBAdobe PDFView/Open
WoS 2182.pdf
  Restricted Access
112.56 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.