Please use this identifier to cite or link to this item:
https://dspace.ncfu.ru/handle/20.500.12258/25581Full metadata record
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Zvada, P. A. | - |
| dc.contributor.author | Звада, П. А. | - |
| dc.contributor.author | Zelensky, E. G. | - |
| dc.contributor.author | Зеленский, Е. Г. | - |
| dc.contributor.author | Kononov, Y. G. | - |
| dc.contributor.author | Кононов, Ю. Г. | - |
| dc.contributor.author | Kostyukova, S. S. | - |
| dc.contributor.author | Костюкова, С. С. | - |
| dc.contributor.author | Dernin, E. I. | - |
| dc.contributor.author | Дернин, Е. И. | - |
| dc.date.accessioned | 2023-09-29T13:22:29Z | - |
| dc.date.available | 2023-09-29T13:22:29Z | - |
| dc.date.issued | 2021 | - |
| dc.identifier.citation | Zvada, P., Zelenskii, E., Kononov, Y., Kostyukova, S., Dernin, E. Research of dependences of idle losses of transformers TM-400/10 on voltage according to synchronous measurements // E3S Web of Conferences. - 2021. - 279, статья № 01022. - DOI: 10.1051/e3sconf/202127901022 | ru |
| dc.identifier.uri | http://hdl.handle.net/20.500.12258/25581 | - |
| dc.description.abstract | The article presents the dependences of the active and reactive components of the losses of the idle transformer on the mains voltage. It is proposed to evaluate the no-load losses using an alternative method for identifying the parameters of the transformer based on high-precision synchronous measurements. Within the framework of a pilot project on a real feeder, using the technology of synchronous measurements, the dependences of no-load losses on voltage were identified. For transformers installed in a distribution network, the dependence of losses on voltage is not quadratic, but has a higher order. It was determined that the dependence of losses in a transformer on voltage for active power has a power of 6.35, and for reactive power has a power of 7.4. | ru |
| dc.language.iso | en | ru |
| dc.relation.ispartofseries | E3S Web of Conferences | - |
| dc.subject | Transformers TM-400/10 | ru |
| dc.subject | Synchronous measurements | ru |
| dc.subject | Idle losses | ru |
| dc.title | Research of dependences of idle losses of transformers TM-400/10 on voltage according to synchronous measurements | ru |
| dc.type | Статья | ru |
| vkr.inst | Инженерный институт | ru |
| Appears in Collections: | Статьи, проиндексированные в SCOPUS, WOS | |
Files in This Item:
| File | Size | Format | |
|---|---|---|---|
| scopusresults 2788 .pdf Restricted Access | 134.38 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.