Please use this identifier to cite or link to this item:
https://dspace.ncfu.ru/handle/20.500.12258/25581| Title: | Research of dependences of idle losses of transformers TM-400/10 on voltage according to synchronous measurements |
| Authors: | Zvada, P. A. Звада, П. А. Zelensky, E. G. Зеленский, Е. Г. Kononov, Y. G. Кононов, Ю. Г. Kostyukova, S. S. Костюкова, С. С. Dernin, E. I. Дернин, Е. И. |
| Keywords: | Transformers TM-400/10;Synchronous measurements;Idle losses |
| Issue Date: | 2021 |
| Citation: | Zvada, P., Zelenskii, E., Kononov, Y., Kostyukova, S., Dernin, E. Research of dependences of idle losses of transformers TM-400/10 on voltage according to synchronous measurements // E3S Web of Conferences. - 2021. - 279, статья № 01022. - DOI: 10.1051/e3sconf/202127901022 |
| Series/Report no.: | E3S Web of Conferences |
| Abstract: | The article presents the dependences of the active and reactive components of the losses of the idle transformer on the mains voltage. It is proposed to evaluate the no-load losses using an alternative method for identifying the parameters of the transformer based on high-precision synchronous measurements. Within the framework of a pilot project on a real feeder, using the technology of synchronous measurements, the dependences of no-load losses on voltage were identified. For transformers installed in a distribution network, the dependence of losses on voltage is not quadratic, but has a higher order. It was determined that the dependence of losses in a transformer on voltage for active power has a power of 6.35, and for reactive power has a power of 7.4. |
| URI: | http://hdl.handle.net/20.500.12258/25581 |
| Appears in Collections: | Статьи, проиндексированные в SCOPUS, WOS |
Files in This Item:
| File | Size | Format | |
|---|---|---|---|
| scopusresults 2788 .pdf Restricted Access | 134.38 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.